Hiossen
-
Ø5.0 ESR Guide - Nobel Biocare (MKIII)
• Connected to the implant to center and prevent shaking of thereverse driver, SR drill and retap• Choose spec of guide according to implant type and diameter (6 overseas companies'... -
Ø3.75 ESR Guide - Nobel Biocare (MKIII)
• Connected to the implant to center and prevent shaking of thereverse driver, SR drill and retap• Choose spec of guide according to implant type and diameter (6 overseas companies'... -
Ø3.3 ESR Guide - Nobel Biocare (MKIII)
• Connected to the implant to center and prevent shaking of thereverse driver, SR drill and retap• Choose spec of guide according to implant type and diameter (6 overseas companies'... -
Ø6.0 ESR Guide - Nobel Biocare (Replace)
• Connected to the implant to center and prevent shaking of thereverse driver, SR drill and retap• Choose spec of guide according to implant type and diameter (6 overseas companies'... -
Ø5.0 ESR Guide - Nobel Biocare (Replace)
• Connected to the implant to center and prevent shaking of thereverse driver, SR drill and retap• Choose spec of guide according to implant type and diameter (6 overseas companies'... -
Ø4.3 ESR Guide - Nobel Biocare (Replace)
• Connected to the implant to center and prevent shaking of thereverse driver, SR drill and retap• Choose spec of guide according to implant type and diameter (6 overseas companies'... -
Ø4.3 ESR Guide - Nobel Biocare (Active)
• Connected to the implant to center and prevent shaking of thereverse driver, SR drill and retap• Choose spec of guide according to implant type and diameter (6 overseas companies'... -
Ø3.5 ESR Guide - Nobel Biocare (Active)
• Connected to the implant to center and prevent shaking of thereverse driver, SR drill and retap• Choose spec of guide according to implant type and diameter (6 overseas companies'... -
Ø7.0 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2... -
Ø6.0 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2... -
SS Wide Excellent Solid Protect Cap
• Protects the solid abutment and minimizes patient irritation• Can be used as the base for a provisional crown -
Ø5.0 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2... -
Ø4.5 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2... -
Ø4.5 Mini ET Transfer Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2... -
-
Reverse Drill
• Used to remove a fractured screw• To be used in conjunction with the guide• If the red marking of the reverse driver is visible on the guide, remove the fractured screw using a... -
Ø4.5 Mini ET Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2... -
Screw Holder
• Grasps onto a protruding fractured screw to unscrew it• Color-coded for easy recognition• Rotation direction: counterclockwise -
Ø4.0 Regular ET Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2... -
Re-Tap
• Re-threads the internal connection of a implant• Connects to a torque wrench or ratchet wrench to re-thread by hand