GBR Kit

GBR Kit

  • GBR Kit

    GBR Kit

    • Our GBR (Guided bone regeneration) kit offers all the tools that can fix shielding membrane,    fix block bone, and collect autogenous bone.  
  • OssBuilder Kit

    OssBuilder Kit

    • Incorporates all necessary tools for GBR procedure• Convenient GBR procedure by using OssBuilder OB2 and OB3, along with OB anchor, cover cap and healing cap.• Use of tenting screw allows users to deal with extensive vertical bone loss...
  • Hand Driver

    Hand Driver

    • Manual driver• Tip holding function (except internal hex type)• Internal hex type length: 11mm
  • Machine Screw Driver

    Machine Screw Driver

    • Driver for engine• Tip holding feature (except internal hex type)• Internal hex type length : 8
  • Bone Ejector

    Bone Ejector

    •Surgical tool for ejecting the harvested autogenous bone from the stopper
  • Ø6.0 AutoBone Stopper

    Ø6.0 AutoBone Stopper

    •Stops at a drilling depth of 4mm for harvesting of cortical bone•Stores the autogenous bone harvested from drilling
  • Ø5.0 AutoBone Stopper

    Ø5.0 AutoBone Stopper

    •Stops at a drilling depth of 4mm for harvesting of cortical bone•Stores the autogenous bone harvested from drilling
  • Ø4.0 AutoBone Stopper

    Ø4.0 AutoBone Stopper

    •Stops at a drilling depth of 4mm for harvesting of cortical bone•Stores the autogenous bone harvested from drilling
  • Ø3.0 AutoBone Stopper

    Ø3.0 AutoBone Stopper

    •Stops at a drilling depth of 4mm for harvesting of cortical bone•Stores the autogenous bone harvested from drilling
  • Ø6.0 AutoBone Collector

    Ø6.0 AutoBone Collector

    •Comes in Ø 3.0 to 6.0 in diameter and a Drill + Stopper set•Recommended drilling speed : 300 ~ 600rpm•Use of drill and stopper : 50 times??Before initial drilling, connect the stopper to the first stage locking and...
  • Ø5.0 AutoBone Collector

    Ø5.0 AutoBone Collector

    •Comes in Ø 3.0 to 6.0 in diameter and a Drill + Stopper set•Recommended drilling speed : 300 ~ 600rpm•Use of drill and stopper : 50 times??Before initial drilling, connect the stopper to the first stage locking and...
  • Ø4.0 AutoBone Collector

    Ø4.0 AutoBone Collector

    •Comes in Ø 3.0 to 6.0 in diameter and a Drill + Stopper set•Recommended drilling speed : 300 ~ 600rpm•Use of drill and stopper : 50 times??Before initial drilling, connect the stopper to the first stage locking and...
  • Ø3.0 AutoBone Collector

    Ø3.0 AutoBone Collector

    •Comes in Ø 3.0 to 6.0 in diameter and a Drill + Stopper set•Recommended drilling speed : 300 ~ 600rpm•Use of drill and stopper : 50 times??Before initial drilling, connect the stopper to the first stage locking and...
  • Tenting Screw

    Tenting Screw

    • Shorter than external type for ease of suturing• Utilized in place of implant for inadequate bone mass or narrow ridge• Compatible with OB2 and OB3• Recommended placement depth: hard/normal bone 3~5mm, soft bone 5mm or more•...
  • Ø3.5 OssBuilder Anchor (EK)

    Ø3.5 OssBuilder Anchor (EK)

    •Exclusively for EK implant (shoulder contact)•Compatible with OB2 and OB3•Tightened with a 0.9 hex hand drive•Recommended tightening torque : 12~15Ncm•C=Connection??Disposable. Do not reuse
  • Regular OssBuilder Anchor (ET)

    Regular OssBuilder Anchor (ET)

    •Exclusively for ET implant (shoulder contact)•Compatible with OB2 and OB3•Tightened with a 0.9 hex hand drive•Recommended tightening torque : 12~15Ncm•C=Connection??Disposable. Do not reuse
  • Mini OssBuilder Anchor (ET)

    Mini OssBuilder Anchor (ET)

    •Exclusively for ET implant (shoulder contact)•Compatible with OB2 and OB3•Tightened with a 0.9 hex hand drive•Recommended tightening torque : 12~15Ncm•C=Connection??Disposable. Do not reuse
  • Ø4.0 Cover Cap (EK/ET)

    Ø4.0 Cover Cap (EK/ET)

    •Submerged procedure•Compatible with OB2 and OB3•Tightened with a 0.9 hex hand drive•Recommended tightening torqu??Disposable. Do not reuse
  • Ø5.0 Healing Cap (EK/ET)

    Ø5.0 Healing Cap (EK/ET)

    Healing Cap (EK/ET)•Non-submerged procedure•Compatible with OB2 and OB3•Tightened with a 0.9 hex hand drive•Recommended tightening torque : 5~8Ncm??Disposable. Do not reuse        
  • Ø4.0 Healing Cap (EK/ET)

    Ø4.0 Healing Cap (EK/ET)

    Healing Cap (EK / ET)•Non-submerged procedure•Compatible with OB2 and OB3•Tightened with a 0.9 hex hand drive•Recommended tightening torque : 5~8Ncm??Disposable. Do not reuse        
  • Ø1.5 Tenting Screw Drill

    Ø1.5 Tenting Screw Drill

    •Use in drilling before inserting the tenting screw•Hard bone : Ø 1.5 / normal, soft bone : Ø 1.0 drill•Laser marking : 1, 2, 3, 4, 5, 6, 7, and 8mm marking lines•Recommended drilling speed : 1,200 ~1,500rpm•Size of...
  • Ø1.0 Tenting Screw Drill

    Ø1.0 Tenting Screw Drill

    •Use in drilling before inserting the tenting screw•Hard bone : Ø 1.5 / normal, soft bone : Ø 1.0 drill•Laser marking : 1, 2, 3, 4, 5, 6, 7, and 8mm marking lines•Recommended drilling speed : 1,200 ~1,500rpm•Size...