Prosthetics

Prosthetics

  • Ø4.5 ET Regular Bite Impression Coping

    Ø4.5 ET Regular Bite Impression Coping

    • Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver
  • Ø4.5 ET Mini Bite Impression Coping

    Ø4.5 ET Mini Bite Impression Coping

    • Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver
  • Ø4.0 ET Mini Bite Impression Coping

    Ø4.0 ET Mini Bite Impression Coping

    • Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver
  • Ø5.0 EK Bite Impression Coping

    Ø5.0 EK Bite Impression Coping

    • Components designed for bite impressions at implant level• 2-in-1 tool for bite and impression taking• Utilizes a technique akin to transfer impression coping for impression taking• Hand tighten with the bite impression coping...
  • Ø4.5 EK Bite Impression Coping

    Ø4.5 EK Bite Impression Coping

    • Components designed for bite impressions at implant level• 2-in-1 tool for bite and impression taking• Utilizes a technique akin to transfer impression coping for impression taking• Hand tighten with the bite impression coping...
  • Ø4.0 EK Bite Impression Coping

    Ø4.0 EK Bite Impression Coping

    • Components designed for bite impressions at implant level• 2-in-1 tool for bite and impression taking• Utilizes a technique akin to transfer impression coping for impression taking• Hand tighten with the bite impression coping...
  • EK/ET Rigid Lab Analog

    EK/ET Rigid Lab Analog

    • Replicate of Rigid abutment for accurate orientation on model after impression• Color coded by height
  • EK/ET Burn-out Cylinder

    EK/ET Burn-out Cylinder

    • Replacement for resin cap before wax up• Delivery of perfect margin with proper fitting after casting
  • EK/ET Rigid Retraction Cap

    EK/ET Rigid Retraction Cap

    • Used for accurate margin reproduction when taking a direct impression• Can be used as the base for a provisional crown• Available for transfer abutment (Ø4.0 excluded)
  • EK/ET Rigid Impression Coping

    EK/ET Rigid Impression Coping

    • Impression components for rigid abutment• Color coded by height• Available for transfer abutment (Ø4.0 excluded)
  • SS Wide Solid Burn-out Cylinder

    SS Wide Solid Burn-out Cylinder

    • Solid abutment components that reproduce them on the model after impression taking• Sophisticated prosthesis can be produced inside• After casting, remove the lower part of the margin holding part
  • SS Regular Solid Burn-out Cylinder

    SS Regular Solid Burn-out Cylinder

    • Solid abutment components that reproduce them on the model after impression taking• Sophisticated prosthesis can be produced inside• After casting, remove the lower part of the margin holding part
  • EK/ET Rigid Protect Cap

    EK/ET Rigid Protect Cap

    • Protects the rigid abutment until applying the final prosthesis• Can be used as the base for a provisional crown• Available for transfer abutment (Ø4.0 excluded)
  • Ø5.0 EK Transfer Abutment

    Ø5.0 EK Transfer Abutment

    • Abutment for cement-retained/combination prosthesis at implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• EK abutment holding system simplifies abutment seating when...
  • Ø4.5 EK Transfer Abutment

    Ø4.5 EK Transfer Abutment

    • Abutment for cement-retained/combination prosthesis at implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• EK abutment holding system simplifies abutment seating when...
  • Ø4.0 EK Transfer Abutment

    Ø4.0 EK Transfer Abutment

    • Abutment for cement-retained/combination prosthesis at implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• EK abutment holding system simplifies abutment seating when...
  • Ø7.0 Regular ET Rigid Abutment

    Ø7.0 Regular ET Rigid Abutment

    • Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...
  • Ø6.0 Regular ET Rigid Abutment

    Ø6.0 Regular ET Rigid Abutment

    • Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...
  • Ø5.0 Regular ET Rigid Abutment

    Ø5.0 Regular ET Rigid Abutment

    • Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...
  • Ø4.5 Regular ET Rigid Abutment

    Ø4.5 Regular ET Rigid Abutment

    • Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...
  • Ø4.0 Mini ET Rigid Abutment

    Ø4.0 Mini ET Rigid Abutment

    • Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...
  • EK Rigid Abutment

    EK Rigid Abutment

      • Cement-retained prosthesis• Abutment level impression• Ø4.0: torque using the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque using the outer driver or 1.2 hex driver• Ø7.0: torque using a 1...
  • SS Wide Solid Lab Analog

    SS Wide Solid Lab Analog

    • Components that replace resin caps before wax up using solid abutments• Used in the same color as solid impression coping
  • SS Closing Screw

    SS Closing Screw

    • Select appropriate mount according to the implant platform• Tighten with a 1.2 hex hand driver
  • SS Regular Solid Lab Analog

    SS Regular Solid Lab Analog

    • Components that replace resin caps before wax up using solid abutments• Used in the same color as solid impression coping
  • SS Cover Screw

    SS Cover Screw

    • Select appropriate mount according to the implant platform• Tighten with a 1.2 hex hand driver
  • SS Wide Solid Impression Coping

    SS Wide Solid Impression Coping

    • Components for solid abutment impression• Possibility of precise prosthesis using lab analog• Color coded by abutment height
  • ET Regular Cover Screw

    ET Regular Cover Screw

    • Depending on the depth of the implant, height (H) is selected• Ø3.2 implant uses exclusive cover screw• Tighten by hand with 1.2 hex driver
  • SS Wide Solid Protect Cap

    SS Wide Solid Protect Cap

    • Protects the solid abutment and minimizes patient irritation• Can be used as the base for a provisional crown
  • ET Mini Cover Screw

    ET Mini Cover Screw

    • Depending on the depth of the implant, height (H) is selected• Ø3.2 implant uses exclusive cover screw• Tighten by hand with 1.2 hex driver