Prosthetics
-
Locator® R-Tx Denture Attachment Processing Assembly
• Permanently attached into the overdenture allowing the Retention Inserts to pivot during insertion and removal• Packing unit: 4ea -
Ø6.0 SS Wide Solid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.8: Torque using a solid abutment driver (code: SDSL/SDSS)• Ø6.0: Torque using a 1.2 hex driver or solid abutment driver• Recommended tightening torque:... -
Locator® R-Tx Impression Coping
• Used to transfer the position of the abutment from the mouth into the model -
Locator® R-Tx Abutment Analog
• Inserted into the Impression Coping• Packaged in three dimensions to accommodate smaller and larger sized implants -
Ø4.8 SS Regular Solid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.8: Torque using a solid abutment driver (code: SDSL/SDSS)• Ø6.0: Torque using a 1.2 hex driver or solid abutment driver• Recommended tightening torque:... -
Ø6.0 ET Regular Convertible Abutment
• Screw-retained prosthesis in multiple scenarios• Angle compensation up to 60°• Torque using convertible abutment outer driver - Ø4.0: torque using o-ring abutment driver (code: AORD) - Ø5.0/6... -
Locator® R-Tx Block Out Spacers
• Blocks out undercut areas immediately• Surrounds the abutment• Keeps the rim of the Denture Attachment Housing clean during the pick-up -
Ø5.0 ET Regular Convertible Abutment
• Screw-retained prosthesis in multiple scenarios• Angle compensation up to 60°• Torque using convertible abutment outer driver - Ø4.0: torque using o-ring abutment driver (code: AORD) - Ø5.0/6... -
Ø4.0 ET Regular Convertible Abutment
• Screw-retained prosthesis in multiple scenarios• Angle compensation up to 60°• Torque using convertible abutment outer driver - Ø4.0: torque using o-ring abutment driver (code: AORD) - Ø5.0/6... -
Locator® R-Tx Processing Spacer
• Creates a recess in the overdenture• Allows the Denture Attachment Housing to be seated without any interference• Along with the surrounding overdenture acrylic. -
Ø4.0 ET Mini Convertible Abutment
• Screw-retained prosthesis in multiple scenarios• Angle compensation up to 60°• Torque using convertible abutment outer driver - Ø4.0: torque using o-ring abutment driver (code: AORD) - Ø5.0/6... -
Ø3.5 ET Regular Stud Abutment
• Retains overdenture with O-ring system• Angle compensation up to 20°• Torque using O-ring driver (code: AORD)• Recommended tightening torque: 30Ncm (mini/regular)• Ball head diameter• Normal size: Ø2.25 (H 3... -
Ø3.5 ET Mini Stud Abutment
• Retains overdenture with O-ring system• Angle compensation up to 20°• Torque using O-ring driver (code: AORD)• Recommended tightening torque: 30Ncm (mini/regular)• Ball head diameter• Normal size: Ø2.25 (H 3... -
Ø3.5 EK Stud Abutment
• Retains overdenture with O-ring system• Angle compensation up to 20°• Torque using O-ring driver (code: HAORD)• Recommended tightening torque: 30Ncm (mini/regular)• Ball head diameter• Normal size: Ø2.25 (H 3... -
Locator® R-Tx Retention Insert
• Nylon Inserts pivot within the Denture Attachment Housing during the insertion and removal of the overdenture• Packing unit: 4ea -
Locator® FIXED Tool Tip Wrench
• Tighten the seating or removal tip on the Locator FIXED® Seating and Removal tool from spinning -
Locator® FIXED Tool 2.4mm Hex Wrench
• Used to tighten or loosen the wire loop in the LOCATOR FIXED® Removal Tip -
Locator® FIXED Removal Tip
• Replacement removal tip for the LOCATOR FIXED® Seating and Removal Tool. -
Locator®FIXED Seating Tip
• Replacement seating tip for the LOCATOR FIXED® Seating and Removal Tool. -
Locator® Fixed Seating and Removal Tool
• Includes: Tool, Seating Tip, Removal Tip, Wire and Level Wrench, and a Tip Wrench.• For seating and removing the prosthesis retained by the LOCATOR FIXED®• Compatible with legacy Locator F-tx Abutments -
Locator® FIXED Housing Assembly (10pk)
• Gold Housing for LOCATOR FIXED®• Backward compatible and can be used with Locator® standard and extended inserts• Packing unit: 10ea -
Locator® FIXED Housing Assembly (4pk)
• Gold Housing for LOCATOR FIXED®• Backward compatible and can be used with Locator® standard and extended inserts• Packing unit: 4ea -
Locator® FIXED Processing Package
• Contains- 1 Gold LOCATOR FIXED® Denture Housing- 1 Green or Blue or Tan LOCATOR FIXED® Insert- 1 LOCATOR ® & Processing Spacer- 1 LOCATOR ® & Black Processing Insert What are the Green... -
Locator® FIXED Inserts (10pks)
• Insert only• Used in 4 implant fixed, full-arch cases• Green - Cannot be used with LOCATOR FIXED® Blue or Tan inserts• Blue - Used in combination with LOCATOR FIXED® Tan anterior/posterior insert• Tan - Used in... -
Locator® FIXED Inserts (2pks)
• Insert only• Used in 4 implant fixed, full-arch cases• Green - Cannot be used with LOCATOR FIXED® Blue or Tan inserts• Blue - Used in combination with LOCATOR FIXED® Tan anterior/posterior insert• Tan - Used in... -
Enhanced Locator® Core Tool
• One streamlined tool compatible with LOCATOR Removable and LOCATOR FIXED Inserts• Two-sided instrument designed for easy insertion and removal of any LOCATOR Insert- Insertion Tip: Effortlessly pickup inserts for transfer and placement in... -
Ø6.0 Regular Convertible Polishing Protector
• Protects GoldCast/plastic cylinder joints duringpolishing process• Tighten with a 1.2 hex hand driver -
Ø4.0 Mini/Regular Convertible Polishing Protector
• Protects GoldCast/plastic cylinder joints duringpolishing process• Tighten with a 1.2 hex hand driver -
Ø6.0 Regular Convertible Lab Analog
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + EbonyGold screw -
Ø5.0 Regular Convertible Lab Analog
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + EbonyGold screw -
-
Ø4.0 Mini/Regular Convertible Lab Analog
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + EbonyGold screw -
Ø6.0 Regular Convertible Protect Cap
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + EbonyGold screw -
Ø5.0 Regular Convertible Protect Cap
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + EbonyGold screw -
Ø4.0 Mini/Regular Convertible Protect Cap
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + EbonyGold screw -
Locator® Core Tool
• Places and removes nylon retentive males in the denture cap• Divides into three separate tools: includes a hand driver for locator abutment -
Ø6.0 Regular Convertible Transfer Impression Coping
• Transfer impression coping• Connected with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin -
Ø4.0 Mini/Regular Convertible Transfer Impression Coping
• Transfer impression coping• Connected with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin -
-
Locator® Block Out Spacers
• Block-out spacers used on the heads of the locator abutments.• Seals gap between denture cap and abutment• Packing unit: 20ea