Prosthetics
-
SS Regular Octa Temporary Cylinder
• Provisional prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
SS Wide Octa Gold Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with gold alloy• Cylinder melting point: 1400-1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder... -
SS Regular Octa Gold Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with gold alloy• Cylinder melting point: 1400-1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder... -
SS Wide Octa Protect Cap
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + Ti Screw -
SS Regular Octa Protect Cap
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + Ti Screw -
-
-
SS Wide ComOcta Implant Transfer Impression Coping
• Hand tightened with a 1.2 hex driver• Packing unit: Impression coping body + Guide pin -
Ø4.8 ET Regular Multi Angled Abutment
• Screw-retained prosthesis for multiple prosthetic options• Same platform as the multi abutment• Restorative components: US esthetic low cylinder (regular/non-hex)• Abutment screw included• Torque using a 1.2 hex driver•... -
Ø4.8 ET Mini Multi Angled Abutment
• Screw-retained prosthesis for multiple prosthetic options• Same platform as the multi abutment• Restorative components: US esthetic low cylinder (regular/non-hex)• Abutment screw included• Torque using a 1.2 hex driver•... -
SS Regular ComOcta Implant Transfer Impression Coping
• Hand tightened with a 1.2 hex driver• Packing unit: Impression coping body + Guide pin -
SS ComOcta Implant Pick-up Impression Coping Guide Pin
• Components for implant level impression taking• For open tray impressions• Unique design that is fixed position in the impression material• Connect with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
Ø4.8 EK Multi Angled Abutment
• Screw-retained prosthesis for multiple prosthetic options• Shares the same platform as the multi-angled abutment• Restorative components: US aesthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver... -
Ø4.8 ET Regular Multi Abutment
• Screw-retained prosthesis for multiple prosthetic options• Same platform as the multi angled abutment• Restorative components: US esthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver (code: MAOD)•... -
Ø4.8 ET Mini Multi Abutment
• Screw-retained prosthesis for multiple prosthetic options• Same platform as the multi angled abutment• Restorative components: US esthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver (code: MAOD)•... -
Ø4.8 EK Multi Abutment
• Screw-retained prosthesis for multiple prosthetic options• Shares the same platform as the multi-angled abutment• Restorative components: US aesthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver... -
SS Wide ComOcta Implant Pick-up Impression Coping
• Components for implant level impression taking• For open tray impressions• Unique design that is fixed position in the impression material• Connect with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
SS Regular ComOcta Implant Pick-up Impression Coping
• Components for implant level impression taking• For open tray impressions• Unique design that is fixed position in the impression material• Connect with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
Ø4.5 Regular Quick Temporary Abutment
• Cement/screw-retained type prosthesis • A provisional prosthesis used after immediate loading• Easy to prep or add resin• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm(mini/regular)• Packing... -
Ø4.0 Mini Quick Temporary Abutment
• Cement/screw-retained type prosthesis • A provisional prosthesis used after immediate loading• Easy to prep or add resin• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm(mini/regular)• Packing... -
SS Regular ComOcta Protect Cap
• Protects ComOcta abutment final prosthesis• Can be used as a temporary crown base• Excellent Solid Protect Cap can substitute for wide type -
Ø4.5 ET Regular Temporary Abutment
• Cement/Screw-retained type for temporary prosthesis• Used to make temporary prosthesis after prep• Implant level impression• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm(mini/regular)• Packing unit:... -
Ø4.0 ET Mini Temporary Abutment
• Cement/Screw-retained type for temporary prosthesis• Used to make temporary prosthesis after prep• Implant level impression• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm(mini/regular)• Packing unit:... -
SS Wide Excellent Solid Impression Cap
• An impression cap used when the solid abutment is trimmed• Used with a solid shoulder analog and analog pin -
Ø4.5 EK Temporary Abutment
• Cement/screw-retained temporary prosthesis• Utilized for producing provisional prostheses after prepping• Impressions taken at the implant level• Torqued using a 1.2 hex driver• Recommended torque for tightening: 20Ncm•... -
Ø4.0 EK Temporary Abutment
• Cement/screw-retained temporary prosthesis• Utilized for producing provisional prostheses after prepping• Impressions taken at the implant level• Torqued using a 1.2 hex driver• Recommended torque for tightening: 20Ncm•... -
Ø4.5 ET Regular NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.0 ET Mini NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.5 EK NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.0 EK NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.5 ET Regular GoldCast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken... -
Ø4.0 ET Mini GoldCast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken... -
Ø4.5 EK GoldCast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken... -
Ø4.0 EK Gold Cast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken... -
SS Regular Excellent Solid Impression Cap
• An impression cap used when the solid abutment is trimmed• Used with a solid shoulder analog and analog pin -
SS Wide Excellent Solid Burn-out Cylinder
• Excellent solid abutment components that reproduce this on the model after impression taking• Sophisticated prosthesis can be produced inside• After casting, remove the lower part of the margin holding part -
Scan Body, Link
Scan after connecting to a link abutment for CERECTM, or a scan post Packing unit: 10ea -
SS Regular Excellent Solid Burn-out Cylinder
• Excellent solid abutment components that reproduce this on the model after impression taking• Sophisticated prosthesis can be produced inside• After casting, remove the lower part of the margin holding part -
SS Wide Excellent Solid Lab Analog
• Components that replace resin caps before wax up using solid abutments• Used in the same color as solid impression coping -
SS Regular Excellent Solid Lab Analog
• Components that replace resin caps before wax up using solid abutments• Used in the same color as solid impression coping