Hiossen
-
-
-
-
Twist Drill for EM Kit
Laser markings on drill match implant length specifications (8/10/11.5/13/15 mm)In cortical bone, it is recommended to use the lance drill to drill to the final implant lengthLong type has a stopper... -
Ø1.5 Twist Drill
Laser markings on drill match implant length specifications: (8/10/11.5/13/15 mm)In cortical bone, it is recommended to use the lance drill to drill to the final implant lengthLong type has a... -
Lance Drill
• Laser markings on drill match implant length specifications (8.0 / 10.0 / 11.5 / 13.0 / 15.0 mm)• In cortical bone, it is recommended to use the lance drill to drill to the final implant... -
EM Kit
Anterior Narrow Ridge optimized for MS Fixture placementUsed to place MS Fixtures for the mandibular anterior and narrow bone width areasUsed for MS Fixtures(Narrow Ridge, Denture) placementStraight... -
Cortical Drill for Ultra-Wide
The drill is used to removing cortical bone at the hard bone (for ultra-wide)Dedicated drill for each implant diameterIt is recommended to drill to the bottom of the marking line -
Protect Screw
• Protect the implant’s internal connection when using the SmartBrush 1 & 2• Torque Using a 1.2 hex driver, tighten to about 5Ncm -
SmartBrush 2
• Debride implant• After removing the patient's prosthesis and abutment, connect the protect screw before using• Must use irrigation and suction during polishing• Recommended... -
SmartBrush 1
• Bristle designed for effective debridement of the implant surface• After removing the patient's prosthesis and abutment, connect the protect screw before using• Recommended speed :... -
Core Drill
• Creates a bone lid while forming the lateral window• Cutting edge design based on the CAS drill, enhancing safety• Recommended speed: 1,200 ~ 1,500rpm• Excessive drilling may... -
Ø7.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical... -
Dome Drill
• Forms a bone window and collects autogenous bone simultaneously• Excellent penetration due to the combination of macro and micro cutting edges• Stopper system safely controls the... -
Ø6.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical... -
Ø5.5 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical... -
Ø5.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical... -
Ø4.5 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical... -
Membrane Lifter
Round shape with no cutting edges for safe membrane liftingSelect Membrane Lifter diameter according to the CAS drill diameter used (head diameter: CAS drill diameter -0.2mm)Use CAS stoppers to... -
Ø4.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical...