Prosthetics

Prosthetics

  • Ø6.0 EK FreeForm ST Abutment

    Ø6.0 EK FreeForm ST Abutment

    • Abutment designed for creating cement-retained or combination prostheses• Utilized to modify the contour of abutment margins• Impressions taken at the implant level• Tighten using a 1.2 hex driver• The gingival height is 0.5mm...
  • Ø5.0 EK FreeForm ST Abutment (Straight + Regular)

    Ø5.0 EK FreeForm ST Abutment (Straight + Regular)

    • Abutment designed for creating cement-retained or combination prostheses• Utilized to modify the contour of abutment margins• Impressions taken at the implant level• Tighten using a 1.2 hex driver• The gingival height is 0.5mm...
  • EK Transfer Lab Analog

    EK Transfer Lab Analog

    • Laboratory analog for capturing implant level impressions• There are two variations, each tailored for implants with a diameter of Ø3.5/4.0 or larger
  • Ø4.0 EK FreeForm ST Abutment

    Ø4.0 EK FreeForm ST Abutment

    • Abutment designed for creating cement-retained or combination prostheses• Utilized to modify the contour of abutment margins• Impressions taken at the implant level• Tighten using a 1.2 hex driver• The gingival height is 0.5mm...
  • Ø5.5 Regular ET Angled Abutment

    Ø5.5 Regular ET Angled Abutment

    • Abutment designed for creating cement-retained or combination prostheses• Compensates for implant insertion angles up to 23° without requiring removal• Suitable for implant-level impressions • Tighten using a 1.2 hex...
  • Ø4.5 Regular ET Angled Abutment

    Ø4.5 Regular ET Angled Abutment

    • Abutment designed for creating cement-retained or combination prostheses• Compensates for implant insertion angles up to 23° without requiring removal• Suitable for implant-level impressions • Tighten using a 1.2 hex...
  • Ø4.3 Mini ET Angled Abutment

    Ø4.3 Mini ET Angled Abutment

    • Abutment designed for creating cement-retained or combination prostheses• Compensates for implant insertion angles up to 23° without requiring removal• Suitable for implant-level impressions • Tighten using a 1.2 hex...
  • Ø5.0 EK Angled Abutment

    Ø5.0 EK Angled Abutment

    • Abutment designed for creating cement-retained or combination prostheses• Compensates for implant insertion angles up to 23° without requiring removal• Suitable for implant-level impressions • Tighten using a 1.2 hex...
  • Ø4.5 EK Angled Abutment

    Ø4.5 EK Angled Abutment

    • Abutment designed for creating cement-retained or combination prostheses• Compensates for implant insertion angles up to 23° without requiring removal• Suitable for implant-level impressions • Tighten using a 1.2 hex...
  • Ø4.0 EK Angled Abutment

    Ø4.0 EK Angled Abutment

    • Abutment designed for creating cement-retained or combination prostheses• Compensates for implant insertion angles up to 23° without requiring removal• Suitable for implant-level impressions • Tighten using a 1.2 hex...
  • Ø7.0 EK Regular Transfer Impression Coping

    Ø7.0 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • Ø6.0 EK Regular Transfer Impression Coping

    Ø6.0 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • Ø5.0 EK Regular Transfer Impression Coping

    Ø5.0 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • Ø4.5 EK Regular Transfer Impression Coping

    Ø4.5 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • Ø4.0 EK Regular Transfer Impression Coping

    Ø4.0 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • SS WideSolid Shoulder Analog Pin

    SS WideSolid Shoulder Analog Pin

    • An impression coping component used when the solid abutment is trimmed• Reinforces the narrow part of the abutment• Used with a solid shoulder analog and impression cap
  • SS Regular Solid Shoulder Analog Pin

    SS Regular Solid Shoulder Analog Pin

    • An impression coping component used when the solid abutment is trimmed• Reinforces the narrow part of the abutment• Used with a solid shoulder analog and impression cap
  • SS Wide Solid Shoulder Analog

    SS Wide Solid Shoulder Analog

    • Impression product used when removing solid abutment• Reproducing the platform part of the implant in the work model• Used with solid impression cap and shoulder analog pin
  • SS Regular Solid Shoulder Analog

    SS Regular Solid Shoulder Analog

    • Impression product used when removing solid abutment• Reproducing the platform part of the implant in the work model• Used with solid impression cap and shoulder analog pin
  • Ø7.0 EK Transfer Abutment

    Ø7.0 EK Transfer Abutment

    • Abutment for cement-retained/combination prosthesis at implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• EK abutment holding system simplifies abutment seating when...
  • Ø7.0 EK Regular Pick-up Impression Coping

    Ø7.0 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...
  • Ø6.0 EK Regular Pick-up Impression Coping

    Ø6.0 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...
  • Ø5.0 EK Regular Pick-up Impression Coping

    Ø5.0 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...
  • Ø4.5 EK Regular Pick-up Impression Coping

    Ø4.5 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...
  • Ø4.0 EK Regular Pick-up Impression Coping

    Ø4.0 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...
  • Ø6.0 EK Transfer Abutment

    Ø6.0 EK Transfer Abutment

    • Abutment for cement-retained/combination prosthesis at implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• EK abutment holding system simplifies abutment seating when...
  • Ø5.5 EK Regular Bite Index

    Ø5.5 EK Regular Bite Index

    • The gingival height is 0.5mm higher when engaged in Ø3.5 implant• Attached to the implant to verify bite impression.• Tighten with a 1.2 hex hand driver• Packing unit: 2ea
  • Ø5.0 EK Bite Impression Coping

    Ø5.0 EK Bite Impression Coping

    • Components designed for bite impressions at implant level• 2-in-1 tool for bite and impression taking• Utilizes a technique akin to transfer impression coping for impression taking• Hand tighten with the bite impression coping...
  • Ø4.5 EK Bite Impression Coping

    Ø4.5 EK Bite Impression Coping

    • Components designed for bite impressions at implant level• 2-in-1 tool for bite and impression taking• Utilizes a technique akin to transfer impression coping for impression taking• Hand tighten with the bite impression coping...
  • Ø4.0 EK Bite Impression Coping

    Ø4.0 EK Bite Impression Coping

    • Components designed for bite impressions at implant level• 2-in-1 tool for bite and impression taking• Utilizes a technique akin to transfer impression coping for impression taking• Hand tighten with the bite impression coping...
  • EK/ET Rigid Lab Analog

    EK/ET Rigid Lab Analog

    • Replicate of Rigid abutment for accurate orientation on model after impression• Color coded by height
  • EK/ET Burn-out Cylinder

    EK/ET Burn-out Cylinder

    • Replacement for resin cap before wax up• Delivery of perfect margin with proper fitting after casting
  • EK/ET Rigid Retraction Cap

    EK/ET Rigid Retraction Cap

    • Used for accurate margin reproduction when taking a direct impression• Can be used as the base for a provisional crown• Available for transfer abutment (Ø4.0 excluded)
  • EK/ET Rigid Impression Coping

    EK/ET Rigid Impression Coping

    • Impression components for rigid abutment• Color coded by height• Available for transfer abutment (Ø4.0 excluded)
  • SS Wide Solid Burn-out Cylinder

    SS Wide Solid Burn-out Cylinder

    • Solid abutment components that reproduce them on the model after impression taking• Sophisticated prosthesis can be produced inside• After casting, remove the lower part of the margin holding part