Hiossen
-
EK III NH Implant
EK III NH Implant A narrower and deeper internal connection has increased the wall thickness of the implant A single connection across all diameter helps decrease prosthetic errors and increases... -
ET III NH Regular Implant
ETIII NH Implant Bone level with 11° Morse taper internal hex connection SA Surface coated with low crystalline nano-HA Taper body with corkscrew thread design that acquires superior... -
ET III SA Regular Implant
ETIII SA Implant bone level with 11° Morse taper internal hex connection Taper body with corkscrew thread design that acquires superior initial stability Narrow threads that increase... -
ET IV NH Regular Implant
ET IV NH Implant Bone level with 11º Morse taper internal hex connection Ideal thread design for optimal osseointegration in maxillary sinus and/or soft bone Narrow corkscrew threads... -
ET IV SA Regular Implant
ET IV SA Implant Bone level with 11° Morse taper internal hex connection Ideal thread design for optimal osseointegration in maxillary sinus and/or soft bone Narrow corkscrew threads... -
-
-
Ø5.5 485 Drill
• Included in 485 Kit• A drill for placing short implants in alveolar bone lacking in vertical dimension• Ø 2.2 drill: straight drill• Except for Ø 2.2 drill, the... -
Ø5.0 485 Drill
• Included in 485 Kit• A drill for placing short implants in alveolar bone lacking in vertical dimension• Ø 2.2 drill: straight drill• Except for Ø 2.2 drill, the... -
Ø4.5 485 Drill
• Included in 485 Kit• A drill for placing short implants in alveolar bone lacking in vertical dimension• Ø 2.2 drill: straight drill• Except for Ø 2.2 drill, the... -
Ø4.0 485 Drill
• Included in 485 Kit• A drill for placing short implants in alveolar bone lacking in vertical dimension• Ø 2.2 drill: straight drill• Except for Ø 2.2 drill, the... -
Ø2.2 Twist Drill for 485 Kit
• Included in 485 Kit• A drill for placing short implants in alveolar bone lacking in vertical dimension• Ø 2.2 drill: straight drill• Except for Ø 2.2 drill, the... -
Repair Torque Driver
• Reduced diameter of shank compared to the Torque Driver (Ø2.1 → 1.6)• The diameter of the screw hole can be minimized during prosthetic repair or SCRP procedures -
Angled Torque Driver
• Driver for torque wrench• No holding function• Recommended tightening torque: 30Ncm (excessive torque causes fracture)• Do not remove tube to prevent fragmentation when... -
Torque Driver
• Driver for torque wrench• Tip holding function• May bend or break if excessive torque is applied• Damage is possible even at low torque if not fully engaged• Apply... -
Tenting Screw
• Shorter than external type for ease of suturing• Utilized in place of implant for inadequate bone mass or narrow ridge• Compatible with OB2 and OB3• Recommended placement... -
ET III NH Mini Implant
ET III NH Implant Bone level with 11° Morse taper internal hex connection SA Surface coated with low crystalline nano-HA Taper body with corkscrew thread design that acquires... -
ET III NH Ultra-Wide Implant
ETIII NH Implant Bone level with 11° Morse taper internal hex connection SA Surface coated with low crystalline nano-HA Taper body with corkscrew thread design that acquires superior... -
ET III SA Ultra-Wide Implant
ETIII SA Implant bone level with 11° Morse taper internal hex connection Taper body with corkscrew thread design that acquires superior initial stability Narrow threads that increase... -
ET III SA Mini Implant
ETIII SA Implant bone level with 11° Morse taper internal hex connection Taper body with corkscrew thread design that acquires superior initial stability Narrow threads that increase...