Prosthetics
-
Ø4.5 ET Regular Angled Abutment Selector
• Used for selecting Angled Abutment A or B type, diameter, and G/H when in oral cavity or in a working model -
Ø4.3 ET Mini Angled Abutment Selector
• Used for selecting Angled Abutment A or B type, diameter, and G/H when in oral cavity or in a working model -
ET Transfer Lab Analog
• Lab analog for implant level impressions• Select appropriate size according to the implant size -
-
-
Ø7.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø6.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø5.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.5 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.5 ET Mini Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.0 ET Mini Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø7.0 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:... -
Ø6.0 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:... -
Ø5.0 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:... -
Ø4.5 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:... -
Ø4.5 Mini ET Transfer Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex... -
Ø4.5 Mini ET Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex... -
Ø4.0 Regular ET Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex... -
Ø4.0 Mini ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:... -
ET Pick-up Impression Coping Guide Pin
• ET Pick-up (Open Tray) Impression Coping Guide Pin • Mini 11mm Impression Coping with 9mm Guide pin = Mini 15mm Impression Coping with 5mm Guide pin • Regular 11mm Impression Coping with 9mm Guide pin = Regular 15mm Impression Coping... -
Ø7.0 ET Regular Pick-up Impression Coping
• Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin -
Ø6.0 ET Regular Pick-up Impression Coping
• Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin -
Ø5.0 ET Regular Pick-up Impression Coping
• Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin -
Ø4.0 ET Regular Pick-up Impression Coping
• Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin -
Ø4.5 ET Regular Pick-up Impression Coping
• Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin -
Ø4.5 ET Mini Pick-up Impression Coping
• Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin -
Ø4.0 ET Mini Pick-up Impression Coping
• Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin -
Ø5.5 ET Regular Bite Index
• Connected to implant to check the bite impression• Tighten with a 1.2 hex hand driver• Packing unit: 2ea -
Ø4.5 ET Mini Bite Index
• Connected to implant to check the bite impression• Tighten with a 1.2 hex hand driver• Packing unit: 2ea -
Ø5.0 ET Regular Bite Impression Coping
• Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver -
Ø4.5 ET Regular Bite Impression Coping
• Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver -
Ø4.5 ET Mini Bite Impression Coping
• Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver -
Ø4.0 ET Mini Bite Impression Coping
• Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver -
EK/ET Rigid Lab Analog
• Replicate of Rigid abutment for accurate orientation on model after impression• Color coded by height -
EK/ET Burn-out Cylinder
• Replacement for resin cap before wax up• Delivery of perfect margin with proper fitting after casting -
EK/ET Rigid Retraction Cap
• Used for accurate margin reproduction when taking a direct impression• Can be used as the base for a provisional crown• Available for transfer abutment (Ø4.0 excluded) -
EK/ET Rigid Impression Coping
• Impression components for rigid abutment• Color coded by height• Available for transfer abutment (Ø4.0 excluded) -
EK/ET Rigid Protect Cap
• Protects the rigid abutment until applying the final prosthesis• Can be used as the base for a provisional crown• Available for transfer abutment (Ø4.0 excluded) -
Ø7.0 Regular ET Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...