Prosthetics
-
Ø4.8 Esthetic-low Narrow Temporary Cylinder
Narrow Type • Used in fabricating a temporary prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
-
SS Wide Octa Pick-up Impression Coping
• A pick up impression coping for octa abutment• Tighten with a 1.2 hex hand driver• Packing unit:impression coping body + guide pin(*) -
SS Regular Octa Pick-up Impression Coping
• A pick up impression coping for octa abutment• Tighten with a 1.2 hex hand driver• Packing unit:impression coping body + guide pin(*) -
SS Wide Octa Plastic Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with non-precious alloys• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
SS Regular Octa Plastic Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with non-precious alloys• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
SS Wide Octa Temporary Cylinder
• Provisional prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
SS Regular Octa Temporary Cylinder
• Provisional prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
SS Wide Octa Gold Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with gold alloy• Cylinder melting point: 1400-1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder... -
SS Regular Octa Gold Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with gold alloy• Cylinder melting point: 1400-1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder... -
SS Wide Octa Protect Cap
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + Ti Screw -
SS Regular Octa Protect Cap
• Protective cap• Tighten with a 1.2 hex hand driver• Packing unit: protect cap + Ti Screw -
-
-
SS Wide ComOcta Implant Transfer Impression Coping
• Hand tightened with a 1.2 hex driver• Packing unit: Impression coping body + Guide pin -
SS Regular ComOcta Implant Transfer Impression Coping
• Hand tightened with a 1.2 hex driver• Packing unit: Impression coping body + Guide pin -
SS ComOcta Implant Pick-up Impression Coping Guide Pin
• Components for implant level impression taking• For open tray impressions• Unique design that is fixed position in the impression material• Connect with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
Ø4.8 EK Multi Angled Abutment
• Screw-retained prosthesis for multiple prosthetic options• Shares the same platform as the multi-angled abutment• Restorative components: US aesthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver... -
Ø4.8 EK Multi Abutment
• Screw-retained prosthesis for multiple prosthetic options• Shares the same platform as the multi-angled abutment• Restorative components: US aesthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver... -
SS Wide ComOcta Implant Pick-up Impression Coping
• Components for implant level impression taking• For open tray impressions• Unique design that is fixed position in the impression material• Connect with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
SS Regular ComOcta Implant Pick-up Impression Coping
• Components for implant level impression taking• For open tray impressions• Unique design that is fixed position in the impression material• Connect with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
SS Regular ComOcta Protect Cap
• Protects ComOcta abutment final prosthesis• Can be used as a temporary crown base• Excellent Solid Protect Cap can substitute for wide type -
SS Wide Excellent Solid Impression Cap
• An impression cap used when the solid abutment is trimmed• Used with a solid shoulder analog and analog pin -
Ø4.5 EK Temporary Abutment
• Cement/screw-retained temporary prosthesis• Utilized for producing provisional prostheses after prepping• Impressions taken at the implant level• Torqued using a 1.2 hex driver• Recommended torque for tightening: 20Ncm•... -
Ø4.0 EK Temporary Abutment
• Cement/screw-retained temporary prosthesis• Utilized for producing provisional prostheses after prepping• Impressions taken at the implant level• Torqued using a 1.2 hex driver• Recommended torque for tightening: 20Ncm•... -
Ø4.5 EK NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.0 EK NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.5 EK GoldCast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken... -
Ø4.0 EK Gold Cast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken... -
SS Regular Excellent Solid Impression Cap
• An impression cap used when the solid abutment is trimmed• Used with a solid shoulder analog and analog pin -
SS Wide Excellent Solid Burn-out Cylinder
• Excellent solid abutment components that reproduce this on the model after impression taking• Sophisticated prosthesis can be produced inside• After casting, remove the lower part of the margin holding part -
SS Regular Excellent Solid Burn-out Cylinder
• Excellent solid abutment components that reproduce this on the model after impression taking• Sophisticated prosthesis can be produced inside• After casting, remove the lower part of the margin holding part -
SS Wide Excellent Solid Lab Analog
• Components that replace resin caps before wax up using solid abutments• Used in the same color as solid impression coping -
SS Regular Excellent Solid Lab Analog
• Components that replace resin caps before wax up using solid abutments• Used in the same color as solid impression coping -
SS Wide Excellent Solid Impression Coping
• Impression components for Excellent solid abutment• Possibility of precise prosthesis using lab analog• Color coded by abutment height -
SS Regular Excellent Solid Impression Coping
• Impression components for Excellent solid abutment• Possibility of precise prosthesis using lab analog• Color coded by abutment height -
Ø4.8 Esthetic-low Plastic Cylinder
• Cast with non-precious metal alloys• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
Ø4.8 Esthetic-low Gold Cylinder
• Screw-retained prosthesis• Cast with gold alloys• Cylinder melting point: 1400~1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
Multi Combination Cylinder
• Used for producing combination prosthesis in multi abutment• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw• Multi angled abutment can be used (Non-Hex) -
Ø7.0 EK FreeForm ST Abutment
• Abutment designed for creating cement-retained or combination prostheses• Utilized to modify the contour of abutment margins• Impressions taken at the implant level• Tighten using a 1.2 hex driver• The gingival height is 0.5mm...