Prosthetics
-
EK Healing Abutment
• Hand tighten it with a 1.2 hex driver• The gingiva height is 0.5mm higher when engaged in Ø3.5 implant -
Ø6.0 EK Angled Abutment
• Abutment designed for creating cement-retained or combination prostheses• Compensates for implant insertion angles up to 23° without requiring removal• Suitable for implant-level impressions • Tighten using a 1.2 hex... -
Ø6.0 ET Regular Convertible Abutment
• Screw-retained prosthesis in multiple scenarios• Angle compensation up to 60°• Torque using convertible abutment outer driver - Ø4.0: torque using o-ring abutment driver (code: AORD) - Ø5.0/6... -
Ø5.0 ET Regular Convertible Abutment
• Screw-retained prosthesis in multiple scenarios• Angle compensation up to 60°• Torque using convertible abutment outer driver - Ø4.0: torque using o-ring abutment driver (code: AORD) - Ø5.0/6... -
Ø4.0 ET Regular Convertible Abutment
• Screw-retained prosthesis in multiple scenarios• Angle compensation up to 60°• Torque using convertible abutment outer driver - Ø4.0: torque using o-ring abutment driver (code: AORD) - Ø5.0/6... -
Ø4.0 ET Mini Convertible Abutment
• Screw-retained prosthesis in multiple scenarios• Angle compensation up to 60°• Torque using convertible abutment outer driver - Ø4.0: torque using o-ring abutment driver (code: AORD) - Ø5.0/6... -
Ø3.5 ET Regular Stud Abutment
• Retains overdenture with O-ring system• Angle compensation up to 20°• Torque using O-ring driver (code: AORD)• Recommended tightening torque: 30Ncm (mini/regular)• Ball head diameter• Normal size: Ø2.25 (H 3... -
Ø3.5 ET Mini Stud Abutment
• Retains overdenture with O-ring system• Angle compensation up to 20°• Torque using O-ring driver (code: AORD)• Recommended tightening torque: 30Ncm (mini/regular)• Ball head diameter• Normal size: Ø2.25 (H 3... -
Ø3.5 EK Stud Abutment
• Retains overdenture with O-ring system• Angle compensation up to 20°• Torque using O-ring driver (code: HAORD)• Recommended tightening torque: 30Ncm (mini/regular)• Ball head diameter• Normal size: Ø2.25 (H 3... -
EK Laboratory Screw
• Laboratory screw: This is an abutment screw designed specifically for laboratory tasks -
EK Waxing Screw
• Waxing screw: utilized in creating screw-type abutments and transfer jigs by extending the screw hole to the upper section -
Multi Scan Body
• ET multi abutment combination with multiple prosthetic options• Non-hex type• Torque using a 1.2 hex driver -
Multi Ti-Base
• Multi Ti-Base abutment combination for multiple prosthetic options• Used in combination with ET Multi Scan Body• Abutment level impression• Non-hex type• Torque using a 1.2 hex driver• Recommended tightening torque:... -
Ø4.8 Esthetic-low Polishing Protector
• Protects GoldCast/plastic cylinder joints during polishing process• Tighten with a 1.2 hex hand driver -
Ø4.8 Esthetic-low Lab Analog
• Transfer impression coping for esthetic-low abutment• Connected with a 1.2 hex hand driver -
Ø4.8 Esthetic-low Transfer Impression Coping
• Transfer impression coping for esthetic-low abutment• Connected with a 1.2 hex hand driver -
Ø4.8 Esthetic-low Pick-up Impression Coping Guide Pin
• Guide pin for Esthetic-low Pick-up Impression Coping -
Ø4.8 Esthetic-low Pick-up Impression Coping
• Components for implant level impression taking• Pick up impression coping for esthetic-low abutment• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
Ø4.8 Esthetic-low Narrow Temporary Cylinder
Narrow Type • Used in fabricating a temporary prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
-
Ø4.8 ET Regular Multi Angled Abutment
• Screw-retained prosthesis for multiple prosthetic options• Same platform as the multi abutment• Restorative components: US esthetic low cylinder (regular/non-hex)• Abutment screw included• Torque using a 1.2 hex driver•... -
Ø4.8 ET Mini Multi Angled Abutment
• Screw-retained prosthesis for multiple prosthetic options• Same platform as the multi abutment• Restorative components: US esthetic low cylinder (regular/non-hex)• Abutment screw included• Torque using a 1.2 hex driver•... -
Ø4.8 EK Multi Angled Abutment
• Screw-retained prosthesis for multiple prosthetic options• Shares the same platform as the multi-angled abutment• Restorative components: US aesthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver... -
Ø4.8 ET Regular Multi Abutment
• Screw-retained prosthesis for multiple prosthetic options• Same platform as the multi angled abutment• Restorative components: US esthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver (code: MAOD)•... -
Ø4.8 ET Mini Multi Abutment
• Screw-retained prosthesis for multiple prosthetic options• Same platform as the multi angled abutment• Restorative components: US esthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver (code: MAOD)•... -
Ø4.8 EK Multi Abutment
• Screw-retained prosthesis for multiple prosthetic options• Shares the same platform as the multi-angled abutment• Restorative components: US aesthetic low cylinder (regular/non-hex)• Torque using multi abutment outer driver... -
Ø4.5 Regular Quick Temporary Abutment
• Cement/screw-retained type prosthesis • A provisional prosthesis used after immediate loading• Easy to prep or add resin• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm(mini/regular)• Packing... -
Ø4.0 Mini Quick Temporary Abutment
• Cement/screw-retained type prosthesis • A provisional prosthesis used after immediate loading• Easy to prep or add resin• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm(mini/regular)• Packing... -
Ø4.5 ET Regular Temporary Abutment
• Cement/Screw-retained type for temporary prosthesis• Used to make temporary prosthesis after prep• Implant level impression• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm(mini/regular)• Packing unit:... -
Ø4.0 ET Mini Temporary Abutment
• Cement/Screw-retained type for temporary prosthesis• Used to make temporary prosthesis after prep• Implant level impression• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm(mini/regular)• Packing unit:... -
Ø4.5 EK Temporary Abutment
• Cement/screw-retained temporary prosthesis• Utilized for producing provisional prostheses after prepping• Impressions taken at the implant level• Torqued using a 1.2 hex driver• Recommended torque for tightening: 20Ncm•... -
Ø4.0 EK Temporary Abutment
• Cement/screw-retained temporary prosthesis• Utilized for producing provisional prostheses after prepping• Impressions taken at the implant level• Torqued using a 1.2 hex driver• Recommended torque for tightening: 20Ncm•... -
Ø4.5 ET Regular NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.0 ET Mini NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.5 EK NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.0 EK NP-Cast Abutment
• Abutment designed for creating screw-retained prostheses• Used for producing customized casting prosthesis through non-precious alloy• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken at the... -
Ø4.5 ET Regular GoldCast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken... -
Ø4.0 ET Mini GoldCast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken... -
Ø4.5 EK GoldCast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken... -
Ø4.0 EK Gold Cast Abutment
• Abutment designed for creating cement-retained or combination prostheses• Used for producing customized prosthesis through gold alloy casting.• Melting temperature of abutment: 1,400~1,450°C (2552~2822°F)• Impressions taken...