Prosthetics
-
SS Regular ComOcta Implant Pick-up Impression Coping
• Components for implant level impression taking• For open tray impressions• Unique design that is fixed position in the impression material• Connect with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
SS Regular ComOcta Protect Cap
• Protects ComOcta abutment final prosthesis• Can be used as a temporary crown base• Excellent Solid Protect Cap can substitute for wide type -
SS Wide Excellent Solid Impression Cap
• An impression cap used when the solid abutment is trimmed• Used with a solid shoulder analog and analog pin -
SS Regular Excellent Solid Impression Cap
• An impression cap used when the solid abutment is trimmed• Used with a solid shoulder analog and analog pin -
SS Wide Excellent Solid Burn-out Cylinder
• Excellent solid abutment components that reproduce this on the model after impression taking• Sophisticated prosthesis can be produced inside• After casting, remove the lower part of the margin holding part -
SS Regular Excellent Solid Burn-out Cylinder
• Excellent solid abutment components that reproduce this on the model after impression taking• Sophisticated prosthesis can be produced inside• After casting, remove the lower part of the margin holding part -
SS Wide Excellent Solid Lab Analog
• Components that replace resin caps before wax up using solid abutments• Used in the same color as solid impression coping -
SS Regular Excellent Solid Lab Analog
• Components that replace resin caps before wax up using solid abutments• Used in the same color as solid impression coping -
SS Wide Excellent Solid Impression Coping
• Impression components for Excellent solid abutment• Possibility of precise prosthesis using lab analog• Color coded by abutment height -
SS Regular Excellent Solid Impression Coping
• Impression components for Excellent solid abutment• Possibility of precise prosthesis using lab analog• Color coded by abutment height -
Ø4.8 Esthetic-low Plastic Cylinder
• Cast with non-precious metal alloys• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
Ø4.8 Esthetic-low Gold Cylinder
• Screw-retained prosthesis• Cast with gold alloys• Cylinder melting point: 1400~1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
Multi Combination Cylinder
• Used for producing combination prosthesis in multi abutment• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw• Multi angled abutment can be used (Non-Hex) -
Ø5.5 ET Regular Angled Abutment Selector
• Used for selecting Angled Abutment A or B type, diameter, and G/H when in oral cavity or in a working model -
Ø4.5 ET Regular Angled Abutment Selector
• Used for selecting Angled Abutment A or B type, diameter, and G/H when in oral cavity or in a working model -
Ø4.3 ET Mini Angled Abutment Selector
• Used for selecting Angled Abutment A or B type, diameter, and G/H when in oral cavity or in a working model -
ET Transfer Lab Analog
• Lab analog for implant level impressions• Select appropriate size according to the implant size -
-
-
Ø7.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø6.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø5.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.5 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.5 ET Mini Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.0 ET Mini Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø7.0 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:... -
Ø6.0 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:... -
SS Wide Excellent Solid Protect Cap
• Protects the solid abutment and minimizes patient irritation• Can be used as the base for a provisional crown -
SS Regular Excellent Solid Protect Cap
• Protects the solid abutment and minimizes patient irritation• Can be used as the base for a provisional crown -
Ø5.0 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:... -
SS WideSolid Shoulder Analog Pin
• An impression coping component used when the solid abutment is trimmed• Reinforces the narrow part of the abutment• Used with a solid shoulder analog and impression cap -
SS Regular Solid Shoulder Analog Pin
• An impression coping component used when the solid abutment is trimmed• Reinforces the narrow part of the abutment• Used with a solid shoulder analog and impression cap -
Ø4.5 Regular ET Transfer Abutment
• Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:... -
SS Wide Solid Shoulder Analog
• Impression product used when removing solid abutment• Reproducing the platform part of the implant in the work model• Used with solid impression cap and shoulder analog pin -
SS Regular Solid Shoulder Analog
• Impression product used when removing solid abutment• Reproducing the platform part of the implant in the work model• Used with solid impression cap and shoulder analog pin -
SS Wide Solid Impression Cap
• An impression cap used when the solid abutment is trimmed• Used with a solid shoulder analog and analog pin -
Ø4.5 Mini ET Transfer Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex... -
SS Regular Solid Impression Cap
• An impression cap used when the solid abutment is trimmed• Used with a solid shoulder analog and analog pin -
Ø4.5 Mini ET Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...