Prosthetics
-
Ø4.0 Mini/Regular Convertible Pick-up Impression Coping
• Components for implant level impression• A pick-up impression coping• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
Locator® Impression Coping
• Represent the placement and performance of LOCATOR housing and processing components in dental impressions• Packing unit: 4ea -
Ø6.0 Regular Convertible Plastic Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with non-precious alloys• Torque using a 1.2 hex driver• Packing unit: cylinder + Ebony-gold cylinder screw -
Ø5.0 Regular Convertible Plastic Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with non-precious alloys• Torque using a 1.2 hex driver• Packing unit: cylinder + Ebony-gold cylinder screw -
Ø4.0 Mini/Regular Convertible Plastic Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with non-precious alloys• Torque using a 1.2 hex driver• Packing unit: cylinder + Ebony-gold cylinder screw -
Locator® Black Processing Male
• A nylon male used in prosthesis fabrication process• Packing unit: 4ea -
Locator® Extended Replacement Male
• Retention force: - Red: approx. 6N- Green: approx. 12N• Angle compensation up to 20~40°• Packing unit: 4ea -
Ø6.0 Regular Convertible Temporary Cylinder
• Provisional prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
Ø5.0 Regular Convertible Temporary Cylinder
• Provisional prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
Ø4.0 Mini/Regular Convertible Temporary Cylinder
• Provisional prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
Locator® Replacement Male
• Retention force: - Blue: approx. 6N- Pink: approx. 12N- Clear: approx. 22N• Angle compensation up to 20°• Packing unit: 4ea -
Ø6.0 Regular Convertible GoldCast Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with gold alloy• Cylinder melting point: 1400~1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder... -
Ø5.0 Regular Convertible GoldCast Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with gold alloy• Cylinder melting point: 1400~1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder... -
Locator® Male Processing Kit
• Components- Block out spacer/denture cap, black processing male- Replacement male blue/pink/clear• A full range of retentive males are included with each denture cap to allow personalized retention for each specific patient• Locator... -
Ø4.0 Mini/Regular Convertible GoldCast Cylinder
• Screw-retained prosthesis• Customized prosthesis cast with gold alloy• Cylinder melting point: 1400~1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder... -
Ø5.0 Regular Convertible Combination Cylinder
• Combination-retained prosthesis possible• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + EbonyGold cylinder screw -
Ø4.0 Mini/Regular Convertible Combination Cylinder
• Combination-retained prosthesis possible• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + EbonyGold cylinder screw -
Multi Scan Body
• ET multi abutment combination with multiple prosthetic options• Non-hex type• Torque using a 1.2 hex driver -
Multi Ti-Base
• Multi Ti-Base abutment combination for multiple prosthetic options• Used in combination with ET Multi Scan Body• Abutment level impression• Non-hex type• Torque using a 1.2 hex driver• Recommended tightening torque:... -
Ø4.8 Esthetic-low Polishing Protector
• Protects GoldCast/plastic cylinder joints during polishing process• Tighten with a 1.2 hex hand driver -
Ø4.8 Esthetic-low Lab Analog
• Transfer impression coping for esthetic-low abutment• Connected with a 1.2 hex hand driver -
Ø4.8 Esthetic-low Transfer Impression Coping
• Transfer impression coping for esthetic-low abutment• Connected with a 1.2 hex hand driver -
Ø4.8 Esthetic-low Pick-up Impression Coping Guide Pin
• Guide pin for Esthetic-low Pick-up Impression Coping -
Ø4.8 Esthetic-low Pick-up Impression Coping
• Components for implant level impression taking• Pick up impression coping for esthetic-low abutment• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin(*) -
Ø4.8 Esthetic-low Narrow Temporary Cylinder
Narrow Type • Used in fabricating a temporary prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
-
Ø4.8 Esthetic-low Plastic Cylinder
• Cast with non-precious metal alloys• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
Ø4.8 Esthetic-low Gold Cylinder
• Screw-retained prosthesis• Cast with gold alloys• Cylinder melting point: 1400~1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw -
Multi Combination Cylinder
• Used for producing combination prosthesis in multi abutment• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw• Multi angled abutment can be used (Non-Hex) -
Ø5.5 ET Regular Angled Abutment Selector
• Used for selecting Angled Abutment A or B type, diameter, and G/H when in oral cavity or in a working model -
Ø4.5 ET Regular Angled Abutment Selector
• Used for selecting Angled Abutment A or B type, diameter, and G/H when in oral cavity or in a working model -
Ø4.3 ET Mini Angled Abutment Selector
• Used for selecting Angled Abutment A or B type, diameter, and G/H when in oral cavity or in a working model -
ET Transfer Lab Analog
• Lab analog for implant level impressions• Select appropriate size according to the implant size -
-
-
Ø7.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø6.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø5.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.5 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece -
Ø4.0 ET Regular Transfer Impression Coping
• Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece