Prosthetics

Prosthetics

  • Ø4.8 Esthetic-low Narrow Temporary Cylinder

    Ø4.8 Esthetic-low Narrow Temporary Cylinder

    Narrow Type • Used in fabricating a temporary prosthesis (Ti Gr-3)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw
  • Ø4.8 Esthetic-low Plastic Cylinder

    Ø4.8 Esthetic-low Plastic Cylinder

    • Cast with non-precious metal alloys• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw
  • Ø4.8 Esthetic-low Gold Cylinder

    Ø4.8 Esthetic-low Gold Cylinder

    • Screw-retained prosthesis• Cast with gold alloys• Cylinder melting point: 1400~1450°C (2552~2642°F)• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw
  • Multi Combination Cylinder

    Multi Combination Cylinder

    • Used for producing combination prosthesis in multi abutment• Torque using a 1.2 hex driver• Recommended tightening torque: 20Ncm• Packing unit: cylinder + Ti cylinder screw• Multi angled abutment can be used (Non-Hex)
  • ET Transfer Lab Analog

    ET Transfer Lab Analog

    • Lab analog for implant level impressions• Select appropriate size according to the implant size
  • ET Waxing Screw

    ET Waxing Screw

    • Waxing screw: longer screw for making screw-type prosthesis and transfer jigs
  • Ø7.0 ET Regular Transfer Impression Coping

    Ø7.0 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø6.0 ET Regular Transfer Impression Coping

    Ø6.0 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø5.0 ET Regular Transfer Impression Coping

    Ø5.0 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø4.5 ET Regular Transfer Impression Coping

    Ø4.5 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø4.0 ET Regular Transfer Impression Coping

    Ø4.0 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø4.5 ET Mini Transfer Impression Coping

    Ø4.5 ET Mini Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø4.0 ET Mini Transfer Impression Coping

    Ø4.0 ET Mini Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø7.0 Regular ET Transfer Abutment

    Ø7.0 Regular ET Transfer Abutment

    • Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:...
  • Ø6.0 Regular ET Transfer Abutment

    Ø6.0 Regular ET Transfer Abutment

    • Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:...
  • Ø5.0 Regular ET Transfer Abutment

    Ø5.0 Regular ET Transfer Abutment

    • Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:...
  • Ø4.5 Regular ET Transfer Abutment

    Ø4.5 Regular ET Transfer Abutment

    • Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:...
  • Ø4.5 Mini ET Transfer Abutment

    Ø4.5 Mini ET Transfer Abutment

    • Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...
  • Ø4.5 Mini ET Rigid Abutment

    Ø4.5 Mini ET Rigid Abutment

    • Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...
  • Ø4.0 Regular ET Rigid Abutment

    Ø4.0 Regular ET Rigid Abutment

    • Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex...
  • Ø4.0 Mini ET Transfer Abutment

    Ø4.0 Mini ET Transfer Abutment

    • Cement-retained/combination type• Implant level impression• Abutment level impression is available using the rigid impression coping (Ø4.0 excluded)• Torque using a 1.2 hex driver• Recommended tightening torque:...
  • ET Pick-up Impression Coping Guide Pin

    ET Pick-up Impression Coping Guide Pin

    • ET Pick-up (Open Tray) Impression Coping Guide Pin • Mini 11mm Impression Coping with 9mm Guide pin = Mini 15mm Impression Coping with 5mm Guide pin • Regular 11mm Impression Coping with 9mm Guide pin = Regular 15mm Impression Coping...
  • Ø7.0 ET Regular Pick-up Impression Coping

    Ø7.0 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø6.0 ET Regular Pick-up Impression Coping

    Ø6.0 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø5.0 ET Regular Pick-up Impression Coping

    Ø5.0 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø4.0 ET Regular Pick-up Impression Coping

    Ø4.0 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø4.5 ET Regular Pick-up Impression Coping

    Ø4.5 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø4.5 ET Mini Pick-up Impression Coping

    Ø4.5 ET Mini Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø4.0 ET Mini Pick-up Impression Coping

    Ø4.0 ET Mini Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø4.5 ET Mini Bite Index

    Ø4.5 ET Mini Bite Index

    • Connected to implant to check the bite impression• Tighten with a 1.2 hex hand driver• Packing unit: 2ea
  • Ø5.0 ET Regular Bite Impression Coping

    Ø5.0 ET Regular Bite Impression Coping

    • Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver
  • Ø4.5 ET Regular Bite Impression Coping

    Ø4.5 ET Regular Bite Impression Coping

    • Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver
  • Ø4.5 ET Mini Bite Impression Coping

    Ø4.5 ET Mini Bite Impression Coping

    • Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver
  • Ø4.0 ET Mini Bite Impression Coping

    Ø4.0 ET Mini Bite Impression Coping

    • Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver