Prosthetics
-
Ø5.5 ET Regular Bite Index
• Connected to implant to check the bite impression• Tighten with a 1.2 hex hand driver• Packing unit: 2ea -
Ø5.5 EK Regular Bite Index
• The gingival height is 0.5mm higher when engaged in Ø3.5 implant• Attached to the implant to verify bite impression.• Tighten with a 1.2 hex hand driver• Packing unit: 2ea -
Ø5.0 ET Regular Bite Impression Coping
• Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver -
Ø4.5 ET Regular Bite Impression Coping
• Implant level components for impression• Impression and bite registration can be made at the same time• Procedure is same as transfer impression coping• Used with Bite impression coping driver -
Ø5.0 EK Bite Impression Coping
• Components designed for bite impressions at implant level• 2-in-1 tool for bite and impression taking• Utilizes a technique akin to transfer impression coping for impression taking• Hand tighten with the bite impression coping... -
Ø4.5 EK Bite Impression Coping
• Components designed for bite impressions at implant level• 2-in-1 tool for bite and impression taking• Utilizes a technique akin to transfer impression coping for impression taking• Hand tighten with the bite impression coping... -
Ø4.0 EK Bite Impression Coping
• Components designed for bite impressions at implant level• 2-in-1 tool for bite and impression taking• Utilizes a technique akin to transfer impression coping for impression taking• Hand tighten with the bite impression coping... -
Ø7.0 Regular ET Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex... -
Ø6.0 Regular ET Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex... -
Ø5.0 Regular ET Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque with the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque with the outer driver or 1.2 hex driver• Ø7.0: torque with a 1.2 hex... -
EK Rigid Abutment
• Cement-retained prosthesis• Abutment level impression• Ø4.0: torque using the outer driver (code: HORDML/HORDMS)• Ø4.5/5.0/6.0: torque using the outer driver or 1.2 hex driver• Ø7.0: torque using a 1... -
SS Closing Screw
• Select appropriate mount according to the implant platform• Tighten with a 1.2 hex hand driver -
SS Cover Screw
• Select appropriate mount according to the implant platform• Tighten with a 1.2 hex hand driver -
Digital Lab Analog
Digital Lab Analog is designed to be used with 3D printed models to check for proper position and custom abutment specifications. Used with Digital Lab Analog Placement Tools to allow the analog to be placed in the 3D Model easily. Tighten with a 1.2...