Prosthetics

Prosthetics

  • SS Wide O-ring Abutment

    SS Wide O-ring Abutment

    • Retains overdenture with o-ring system• Angle compensation of up to 20°• Torque using an outer driver (code: AORD)• Recommended tightening torque: 30Ncm
  • SS Regular O-ring Abutment

    SS Regular O-ring Abutment

    • Retains overdenture with o-ring system• Angle compensation of up to 20°• Torque using an outer driver (code: AORD)• Recommended tightening torque: 30Ncm
  • SS Regular Octa Abutment (regular+wide)

    SS Regular Octa Abutment (regular+wide)

    • Screw-retained prosthesis for multiple prosthetic options• Angle compensation of up to 60°• Torque using a dedicated outer driver (code: ODSL/ODSS)• Recommended tightening torque: 30Ncm
  • SS Regular ComOcta NP-Cast Abutment

    SS Regular ComOcta NP-Cast Abutment

    • Cement/combination/screw-retained prosthesis• Customized prosthesis cast with non-precious alloy• Abutment fastens to the platform at a 45° angle• Abutment melting point: 1400-1450°C (2552~2642°F)• Implant level...
  • SS ComOcta Angled Abutment (regular+wide)

    SS ComOcta Angled Abutment (regular+wide)

    • Cement/combination-retained prosthesis• Angle compensation between 15°/20°• Use dedicated abutment screw• Implant level impression• Torque using a 1.2 hex driver• Recommended tightening torque: 30Ncm• Packing...
  • SS Regular ComOcta Gold Abutment

    SS Regular ComOcta Gold Abutment

    • Cement/combination/screw-retained prosthesis• Customized prosthesis cast with gold alloy• Abutment fastens to the platform at a 45° angle• Abutment melting point: 1400-1450°C (2552~2642°F)• Implant level...
  • Ø4.8 SS Regular Locator R-Tx Abutment

    Ø4.8 SS Regular Locator R-Tx Abutment

    • Maintain overall user familiarity and processing techniques• All-in-one packaging (Abutment, Denture Attachment Housing, Retention Inserts, Block-out Spacer)• Angle correction up to 30°• Easier retention terminology: zero, low,...
  • Ø4.0 ET Regular Locator R-Tx Abutment

    Ø4.0 ET Regular Locator R-Tx Abutment

    • Maintain overall user familiarity and processing techniques• All-in-one packaging (Abutment, Denture Attachment Housing, Retention Inserts, Block-out Spacer)• Angle correction up to 30°• Easier retention terminology: zero, low,...
  • Ø3.7 ET Regular Locator Legacy Abutment

    Ø3.7 ET Regular Locator Legacy Abutment

      • Genuine Zest Anchors abutment• Angle compensation up to 40°• 1.5mm lower profile with various attachments for stable retention force• Torque using a Locator Outer Driver (code: TWLDSK/TWLDSK)• Recommended tightening...
  • Ø3.7 EK Locator Legacy Abutment

    Ø3.7 EK Locator Legacy Abutment

      • Genuine Zest Anchors abutment• Angle compensation up to 40°• 1.5mm lower profile with various attachments for stable retention force• Torque using a Locator Outer Driver (code: TWLDSK/TWLDSK)• Recommended tightening...
  • ET Transfer Lab Analog

    ET Transfer Lab Analog

    • Lab analog for implant level impressions• Select appropriate size according to the implant size
  • ET Waxing Screw

    ET Waxing Screw

    • Waxing screw: longer screw for making screw-type prosthesis and transfer jigs
  • Ø7.0 ET Regular Transfer Impression Coping

    Ø7.0 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø6.0 ET Regular Transfer Impression Coping

    Ø6.0 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø5.0 ET Regular Transfer Impression Coping

    Ø5.0 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø4.5 ET Regular Transfer Impression Coping

    Ø4.5 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø4.0 ET Regular Transfer Impression Coping

    Ø4.0 ET Regular Transfer Impression Coping

    • Components for Implant level impression with closed tray• Triangular arc ensures accurate placement• Tighten with a 1.2 hex hand driver• Packing unit- Hex: impression coping body + guide pin- Non-hex: impression coping as one piece
  • Ø7.0 EK Regular Transfer Impression Coping

    Ø7.0 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • Ø6.0 EK Regular Transfer Impression Coping

    Ø6.0 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • Ø5.0 EK Regular Transfer Impression Coping

    Ø5.0 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • Ø4.5 EK Regular Transfer Impression Coping

    Ø4.5 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • Ø4.0 EK Regular Transfer Impression Coping

    Ø4.0 EK Regular Transfer Impression Coping

    • Components for implant level impression using an Closed Tray method.• Features a stable triangular arc structure for secure fastening and precise repositioning.• Tighten with a 1.2 hex hand driver.• The gingival height is 0.5mm...
  • Scan Healing Abutment

    Scan Healing Abutment

    Healing abutment with scan body function Specifications are identified by the indents on the abutment head Abutment level impression Has a dedicated driver integrated carrier to tighten 1.2 hex driver / driver integrated carrier Packing unit: scan...
  • ET Pick-up Impression Coping Guide Pin

    ET Pick-up Impression Coping Guide Pin

    • ET Pick-up (Open Tray) Impression Coping Guide Pin • Mini 11mm Impression Coping with 9mm Guide pin = Mini 15mm Impression Coping with 5mm Guide pin • Regular 11mm Impression Coping with 9mm Guide pin = Regular 15mm Impression Coping...
  • Ø7.0 ET Regular Pick-up Impression Coping

    Ø7.0 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø6.0 ET Regular Pick-up Impression Coping

    Ø6.0 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø5.0 ET Regular Pick-up Impression Coping

    Ø5.0 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø4.0 ET Regular Pick-up Impression Coping

    Ø4.0 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø4.5 ET Regular Pick-up Impression Coping

    Ø4.5 ET Regular Pick-up Impression Coping

    • Components for Implant level impression with Open tray• Delivery of accurate internal hex position in the impression material• Tighten with a 1.2 hex hand driver• Packing unit: impression coping body + guide pin
  • Ø7.0 EK Regular Pick-up Impression Coping

    Ø7.0 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...
  • Ø6.0 EK Regular Pick-up Impression Coping

    Ø6.0 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...
  • Ø5.0 EK Regular Pick-up Impression Coping

    Ø5.0 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...
  • Ø4.5 EK Regular Pick-up Impression Coping

    Ø4.5 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...
  • Ø4.0 EK Regular Pick-up Impression Coping

    Ø4.0 EK Regular Pick-up Impression Coping

    • Components for implant level impression using an Open Tray method.• Ensures precise positioning of the internal hex in the impression material.• Tighten with a 1.2 hex hand driver• Packing unit: Impression coping body + guide pin...