Implant Kit
-
122 Taper Kit
Optimized to taper fixture 2 time drilling sequence fixture placement => reducing chair time Built in stopper helps control drilling depth Good cutting force (excellent drilling power) and low ricocheting Color coded to differentiate drill diameter -
485 Kit
485 Kit Prevents damage to the mandibular nerve Safe drilling even with insufficient vertical bone height 3 Easy and Simple drilling steps The round shaped drill prevents damage to the mandibular nerve The round tip of the 485 drill helps... -
122 Parallel Pin
• Parallel pin for 122 Taper Drill• Used for checking position and direction of bone preparation• Lower part for 2.2 drill, upper part for guide drill• 122 Taper Kit single item (excluded from Taper Kit)• Other components same... -
Ultra Kit
• Posterior wide diameter optimized for ultra wide fixture placement• This kit is used to place large diameter fixtures in the posterior area• Need enough bone width• Immediate placement after extraction• Immediate replacement... -
-
-
Taper Cortical Drill
• The drill is used to remove cortical bone of the hard bone (used right after the use of Taper Drill)• Dedicated drill for each implant diameter• F3.5~5.0 drill marking line: bottom line 8.5mm or less, top line 10mm or more implant... -
-
-
Ø4.5 Taper Drill
• Taper drill for taper(III type) implant by diameter and length• Stopper drill with 1mm space• Color coding displays implant diameter• F3.5: yellow, F4.0: green, F4.5: blue, F5.0: red, F5.5: yellow• Taper Kit single item... -
-
-
-
Taper Kit
Optimized to taper fixture Built in stopper helps control drilling depth Good cutting force (excellent drilling power) and low ricocheting Color coded to differentiate drill diameter -
-
-
-
-
-
Driver Separator
• If the MS implant is jammed in the Driver, the Driver Separator can be levered in to separate the two -
Cortical Drill for Ultra-Wide
The drill is used to removing cortical bone at the hard bone (for ultra-wide)Dedicated drill for each implant diameterIt is recommended to drill to the bottom of the marking line -
Ø7.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single... -
Ø6.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single... -
Ø5.5 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single... -
Ø5.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single... -
Ø4.5 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single... -
Ø4.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single... -
Ø3.5 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single... -
Guide Drill for 122 Taper Kit
Forming a hole to facilitate initial drillingBone density determined through drilling -
Ø2.7 Twist Drill for 122 Taper Kit
Used for limited access for the Stopper Drill into the oral cavity -
Depth Gauge
• Releases excessive torque when hand piece does not move due to being stuck in bone during expansion drill removal process.• Use with an open wrench to turn the hex of the Expansion drill • Prevents from over torquing -
-
ET Implant Driver
• Connects directly to an ET implant for final adjustments to the implant's depth• *C = Connection -
Ø2.2 Twist Drill for 122 Taper Kit
For 122 Taper Kit/Taper KitLong stopper (6mm): Enabling a procedure without drill extension for posterior regionThe color coded stopper indicates the drill length. -
Hand Driver
• Manual driver• Tip holding function (except internal hex type)• Internal hex type length: 11mm