Hiossen Kits
-
122 Taper Kit
Optimized to taper fixture 2 time drilling sequence fixture placement => reducing chair time Built in stopper helps control drilling depth Good cutting force (excellent drilling power) and low ricocheting Color coded to differentiate drill diameter -
-
485 Kit
485 Kit Prevents damage to the mandibular nerve Safe drilling even with insufficient vertical bone height 3 Easy and Simple drilling steps The round shaped drill prevents damage to the mandibular nerve The round tip of the 485 drill helps... -
EIR Full Kit
• Maintenance KIT used to remove fractured or damaged fixture without any bone loss• 3 step max fixture removal• No bone loss fixture removal without Trephine Drill• Osseointegrated fixture can be removed with 400Ncm• Same... -
EIR Kit
• Maintenance KIT used to remove fractured or damaged fixture without any bone loss• 3 step max fixture removal• No bone loss fixture removal without Trephine Drill• Osseointegrated fixture can be removed with 400Ncm• Same... -
ESR Full Kit
• Maintenance KIT for Fractured Screw Removal and various abutment failure cases• Fractured Screw Removal success rate is over 90%• Two step max fractured screw removal• SR Drill’s durability and... -
Prosthetic Kit
Prosthetic Kit Hiossen Prosthetic Kit provides the clinician all the necessary tools for the ideal placement of the whole range of attachments within the ET implant system. Reliable solution Reliable and safe restoration for the ideal placement of... -
ESR Kit
• Maintenance KIT for Fractured Screw Removal and various abutment failure cases• Fractured Screw Removal success rate is over 90%• Two step max fractured screw removal• SR Drill’s durability and... -
Prosthetic Simple Kit
Hiossen Prosthetic Simple Kit is designed specifically for restorative doctors Allowing clinicians to easily store and transport the prosthetic tools for Hiossen ET Implant system. The autoclavable kit includes a torque wrench, machine screw drivers... -
IM-Cure Kit
The Im-Cure Kit has been designed to manage peri-implantatis and mucositis disease by removing the causes of inflammation, including plaque, tartar, and foreign bodies from the surface of an implant -
GBR Kit
• Our GBR (Guided bone regeneration) kit offers all the tools that can fix shielding membrane, fix block bone, and collect autogenous bone. -
OssBuilder Kit
• Incorporates all necessary tools for GBR procedure• Convenient GBR procedure by using OssBuilder OB2 and OB3, along with OB anchor, cover cap and healing cap.• Use of tenting screw allows users to deal with extensive vertical bone loss... -
Bone Compaction Kit
• Compacts bone chips into the surrounding bone• Enables safe sinus lift without hydraulic elevation• Creates bone chips and compresses the bone laterally while drilling clockwise• Included components - Ø1.5 Lance... -
OneGuide Kit (EK Only)
• OneGuide Kit has options for open or closed sleeve - Open type is recommended for use in posterior with limited space• Two sizes of guide holes depending on the diameter of the fixture - D5.0 for implant... -
Torque Wrench - Bar Type (30 Ncm)
• Used to adjust the implant location or tighten abutment, screw, etc.• Apply torque by pulling bar to the line indicationg the torque value• Applies up to 30Ncm of torque (markers at 10/20/30Ncm) -
LAS Stopper
• Laser marked numbers indicate the drilling depth• Color-coded by length• Can be used up to 50 times before replacement -
Hydraulic Membrane Lifter Set
• Hydraulic pressure is used to separate and liftthe sinus membrane• Securely fits Ø2.8~Ø4.1 CAS drilled osteotomies -
122 Parallel Pin
• Parallel pin for 122 Taper Drill• Used for checking position and direction of bone preparation• Lower part for 2.2 drill, upper part for guide drill• 122 Taper Kit single item (excluded from Taper Kit)• Other components same... -
Ultra Kit
• Posterior wide diameter optimized for ultra wide fixture placement• This kit is used to place large diameter fixtures in the posterior area• Need enough bone width• Immediate placement after extraction• Immediate replacement... -
-
-
Taper Cortical Drill
• The drill is used to remove cortical bone of the hard bone (used right after the use of Taper Drill)• Dedicated drill for each implant diameter• F3.5~5.0 drill marking line: bottom line 8.5mm or less, top line 10mm or more implant... -
-
-
Ø4.5 Taper Drill
• Taper drill for taper(III type) implant by diameter and length• Stopper drill with 1mm space• Color coding displays implant diameter• F3.5: yellow, F4.0: green, F4.5: blue, F5.0: red, F5.5: yellow• Taper Kit single item... -
-
-
-
Taper Kit
Optimized to taper fixture Built in stopper helps control drilling depth Good cutting force (excellent drilling power) and low ricocheting Color coded to differentiate drill diameter -
-
-
-
-
-
Driver Separator
• If the MS implant is jammed in the Driver, the Driver Separator can be levered in to separate the two -
Ø3.4 Machine Driver (Denture)
• Driver for EM(MS) implants: denture• The triangular marking is used in line with the implant -
Cortical Drill for Ultra-Wide
The drill is used to removing cortical bone at the hard bone (for ultra-wide)Dedicated drill for each implant diameterIt is recommended to drill to the bottom of the marking line -
Ø7.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single... -
Ø6.0 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single... -
Ø5.5 122 Taper Drill
• Taper drill for Type III fixtures• Specification by diameter and length• Color coding displays fixture diameter• One step large-diameter drill is used• to remove cortical bone from the hard bone• 122 Taper Kit single...